ÉNERGIE

CX1000-6



Compteur OFDM monophasé

Gestion tarifaire

Profil de charge programmable

Gestion de la charge par le relais intégré

Coupure a distance par le verrouillage du relais

Lecture et programmation en locale ou a distance

Systeme anti-fraud renforcé

Plateforme de communications

Protocole de communication ouvert

Mise a jour du logiciel a distance

CURRENT
o Current Range = 0.25 - 5 (100) A
o Starting current = 25 mA
o Self-consumption:
o Voltage < 2W and 10VA (without communication)
o Current < 0,025 VA to Ib=5A
o Power supply = 127-230 V
o Frequency = 50/60 Hz


METERING DATA
o 4 quadrant measurements Active and Reactive energy
o Class 1 or 2 accuracy according to IEC 62052-11 & 62053-21 for active energy measurement
o Class B or A accuracy according to EN 50470-1 and EN 50470-3 for active energy measurement
o Class 2 accuracy according to IEC 62052- 23 for reactive energy measurement
o Instantaneous measurement of U, I, P, F
o Average measurement of P, Q and power factor


TARIFF MANAGEMENT
o Real-time clock with 7 day super-cap back-up.
o 4 seasons and 6 tariffs
o Up to 36 registers for energy
o Up to 6 maximum demand registers


RECORDING
o Non-volatile memory E2PROM
o Power failure ride-through
o Load profile
o 2 multitrack groups
o Programmable Independent integration period
o Automatic historical recording of consumption registers
o Historical values


CUSTOMER DISCONNECTION
o disconnection through 120A relay
o phase and neutral
o compliant with UC3 i.e. IEC 62055-31 appendix


COMMUNICATION
LOCAL INTERFACE
  o IEC 62056-21, Mode E
  o Infra Red local communication port
  o RS232/RS485
  o 2A Relay
  o Pulse output
PLC INTERFACE
  o GSM/GPRS
PLC INTERFACE
  o OFDM PRIME
  o OFDM G3
  o Automatic repeat function
  o Plug&Play Technology
EXTERNAL CONTACT INPUT
  o Gas leak detection
  o Remote reconnection of the power breaker
DATA FORMAT
DLMS-COSEM and OBIS


LOCAL METER READING
o Ready for water, gas and heat/cooling meter reading
o 2 wire M-Bus EN 13757 connection
o Master station
o Power up to 4U


MECHANICAL FEATURES
o IP53 protection degree (IEC 60529)
o Fixing Triangle DIN 43857
o Operating Temperature: -25°C to +70°C
o Humidity > 90% at 40°C


CONNECTION
o DIN and BS type


APPLICATION SOFTWARE UPGRADE
o Physical separation between metrological and customisable
software part
o Two bootable memory bank
o MID WELMEZC guide 7.2
o Local or remote download through optical port or PLC



2012 SAGEMCOM | Mentions légales | Contact | Plan du site | Protection des données